Set duty cycle and frequency vi labview 2015 myrio. The pulse width and period of the pwm wave can be calculated by recording the counter value of the signal along the changing moment, so as to calculate the duty cycle. The evaluation of the efficiency was measured by installing the device in a fully automated high. Labview calculates the value using the following equation. Our 50 hz signal has a period of 20 ms, so these pulse widths correspond to duty cycles of 0. However in advanced mode, the operator may override selected settings. Thorlabs your source for fiber optics, laser diodes. On the left side is the channel list, and on the right side is a tree view containing the measurement types in groups. It uses graphical language in creating a virtual instrument vi, which can acquire and process data, display results on a graph, control another instrument andor an. Pressing the add button here or doubleclicking an item adds it to the measurement list. Custom probes definitions for standard picosupplied oscilloscope probes and current clamps are included in the software.
We implemented our solution as a collection of individual virtual instruments, which are then packaged in a toplevel master vi. Labview issue details i would like to measure the frequency and the dutycycle of a pwmsignal pulse width modulated signal using a single physical channel and a single counter. Auto scale, auto gate, risefall time, duty cycle, etc. Nov 29, 2016 theoretically, our duty cycle will range between pulse widths of 1 ms and 2 ms, with 1. Ni labview a comprehensive library of vis and example programs for ni labview that is used to develop. Optomechanics, optics, optoelectronics, laser diodes, fiber optics and ase test. A duty cycle of 50% is maintained when the internal input clock paces operations. Fast measurement speed up to 15,000 readingss, low latency with read interval rate of 66 s high accuracy up to 40 ppm delivers trustworthy results includes dc source, duty cycle, pulse width, counter and offset compensated resistance.
Definitions for standard picosupplied oscilloscope probes and current clamps are included in the software. Pressing the add default measurement button opens the add measurement window. Waveforms toolkit for labview by digilent national. Waveforms toolkit for labview by digilent national instruments. An alternate way to measure duty cycle is dwell, measured in degrees instead of percent. Duty cycle, frequency and pulse widthan explanation youtube. The media on which you receive national instruments software are warranted not to fail to execute. The communication between interfacing circuit on the arduino uno board and labview is possible only by the makerhub. Students use labview to generate a pwm signal and vary its properties, including frequency, step size, and duty cycle, and then output the signal to leds on the mechatronic systems board to control brightness. Using the measured values, you can calculate the duty cycle of the signal. Reading analog values and pwm with labview fpga technical. The ratio of the pulse width to the period is referred to as the duty cycle of the signal. Pulseduty cycle measurement the ni 9361 supports pulse measurements only for compactrio systems.
Usbctr series devices have four 32bit timer outputs. Mar 17, 2017 both dc motor and temperature measurement code is done through labview software loaded into arduino board. As a conclusion, the ni mydaq can be used for power electronic circuit drivers and data acquisition. This standard api supports analog discovery, analog discovery ii, and the electronics explorer, and it includes mso vis to set up measurements and acquire data from mixedsignal oscilloscopes, fgen vis to output waveforms with the function generator, dig vis for reading and writing. Implementation of a programmable electromechanical chopper.
Set duty cycle and frequency vi labview 2015 myrio toolkit. This device avoids the use of mechanisms based on microcontrollers. Adjustable frequency and duty cycle enables exploration of the relationship between output voltage and duty cycle as well as a test for critical frequencies. Pwm ref in specifies the reference to the pwm channel. Both dc motor and temperature measurement code is done through labview software loaded into arduino board. Second, select the digital input module such as the 9401 in the project.
You can take pulse or duty cycle measurements with the ni 9361. Pwm has two main components one is time period and other one is duty cycle. Returns 4 bytes, where the first two bytes least significant word or lsw are a 16bit value representing the number of clock ticks during the high signal, and the second two bytes most significant word or msw are a 16bit value representing the number of. The circuit uses a dc motor as load and a measurement resistor r6 to detect the load current. Duty cycle specifies the percentage of time the pwm signal remains high over one pwm cycle. How to measure the duty cycle of pwm wave national. Real time speed control of a dc motor by temperature. How to use an oscilloscope what is an oscilloscope oscilloscope tutorial duration. If it has been changed, the new duty cycle is set using the daqmx write vi. Labview issue details i would like to measure the frequency and the duty cycle of a pwmsignal pulse width modulated signal using a single physical.
Pulse duty cycle measurement the ni 9361 supports pulse measurements only for compactrio systems. Gate driver of dc dc boost converters using national. A duty cycle of 0 coresponds to 0% on and a duty cycle of 1 coresponds to 100% on. What methods can be used to measure the pwm duty cycle. A duty cycle of 0 coresponds to 0% on and a duty cycle of 255 coresponds to 100% on. A 60% duty cycle is a signal that is on 60% of the time and off 40% of the time. Apr 18, 2016 the time that the led is kept on in relation to it being off is determined by the duty cycle. A benchvue software license bv0007b is now included with your instrument. Usbdio32hs software software support the usbdio32hs is supported by the software in the table below.
Labview measurements manual april 2003 edition part number 322661b01. The software will usually configure these settings automatically, ensuring optimal performance without bothering the operator. I know that there is a pulse width measurement vi in the waveform palette and it can be used to measure the pwms duty cycle and frequency. Create a pid controller on the ni myriothe software projects. This is a digital sensor that provides an output frequency proportional to. Labview is a graphical programming language, as demonstrated in the code snippet below, but understand that it is still a powerful programming language not a simple software tool.
In this class, you will get handson experience configuring and programming ni data acquisition hardware using nidaqmx and labview. With the capacity to support labview graphical programming software via the latest version of its device drivers, the tmx will allow engineers, scientists and other test developers to increase their productivity by communicating host control commands via labview for test cells and automated development platforms. Where can i find a labview program for a pulse generator. An electromechanical chopper with adjustable frequency from 0. Labview measurements manual chalmers university of technology. Frequency must be within the range of 40 hz to 40 khz. For devices that cannot measure frequency directly, you need to use software algorithms, such as the fast fourier transform fft. Frequency, amplitude, duty cycle and dc offset and three. The vi also displays an image of the waveformin labview and allows the user to acquire and save measurement data from the oscilloscope. Since the measurement update rate is quite long, id probably set up some kind of software timer to trigger the duty cycle measurement task only when needed.
Labview vi for interfacing with tektronix mso4000 oscilloscopes. Frequencypulse, or dutycycle measurements up to 1 mhz convenient removable screw. All sourcemeter models provide precision voltage and current sourcing as well as measurement capabilities. The time that the led is kept on in relation to it being off is determined by the duty cycle. The counter measures the high and low durations of a pulse on a signal. Frequency specify the frequency of the pwm signal in hertz. Then if your duty cycle is 10% youll see one sample high and 9 low. Sets the duty cycle value and frequency value of a pulse width modulation pwm signal. Data acquisition using labview nxg course helps you explore the fundamentals of data acquisition using sensors, ni data acquisition hardware, and labview. For example, you can graph the changing duty cycle or frequency of a signal over time. With these additions, the duty cycle control on the front panel is checked every iteration of the loop. When measuring duty cycle, a digital multimeter displays the amount of time the input signal is above or below a fixed. Hello everyone, i have never done labview real time before and have a quite simple question.
Records the high and low time of a signal on the external pin, which provides the duty cycle, pulse width, and period of the signal. From optomechanical components to telecom test instrumentation, thorlabs extensive manufacturing capabilities allow us to ship high quality, well priced components and devices for nextday delivery. The duty cycle is the fraction of a period of the pulse train when the pulse is occurring. In my program i am measuring 2 duty cycles using twice the u3 pwm16 and duty cycle, and using the u6 easy stream example to measure 2 analog inputs. This badge holder can make basic analog and digital measurements, select the right daq hardware based on resolution, range, and sensitivity, and correctly wire the system with proper grounding techniques. Daqmx and measurement and automation explorer provided by labview.
I am running the measures as fast as possible, getting a measure every 4 secs. Feb 28, 20 page 1 of 2 how can i reset the u6 labjack unit. Returns 4 bytes, where the first two bytes least significant word or lsw are a 16bit value representing the number of clock ticks during the high signal, and the second two bytes most significant word or msw are a 16bit value representing the number. Export data to a spreadsheet using write to measurement file function in labview. Each timer can generate a programmable width pulse with a software selectable frequency in the range of 0. Pulse width modulation pwm using nidaqmx and labview. Luckily ni sells hardware both cheap and expensive for this. This standard api supports analog discovery, analog discovery ii, and the electronics explorer, and it includes mso vis to set up measurements and acquire data from mixedsignal oscilloscopes, fgen vis to output waveforms with the function generator, dig vis. Figure below shows a pwm of amplitude 5 volt and timer period is 0. But even this might not be adequate if you need to have more precision in your measurement. Generate pwm for heater control labview labjack forum. Study of the algorithm of auto wheel speed sensor testing based on labview abstract.
So if the user provides 5, youll have a duty cycle of 50. Duty cycle, frequency and pulse widthan explanation. My question is, is it necessary to use this pulse width measurement vi on a real time platform compactrio, compactdaq etc. Measuring digital pulse width, period, and frequency. However, unless the pwm signal is quite clean id think about averaging several measurements to avoid the effects of jitter or a noisey pwm signal. One drawback of using software to calculate the duty cycle is that the processing.
This lab introduces students to pulse width modulation pwm, including the basic mathematical theory and practical application. The energy in a bilevel, or rectangular, pulse is equal to the product of the peak power, p t, and the pulse width, devices to measure energy in a waveform operate on time scales longer than the duration of a. In this course, you will learn the basics of hardware selection, including resolution and sample rate, and the foundation of sensor connectivity, including grounding and wiring configurations. Understand how to use and program the usb6009 daq using support software. Auto wheel speed sensor and target gear are the information sources and key components for auto electronic control system, and it is also one of the core technology in the research field of automotive electronics, it becomes the challenge for auto test sector. Duty cycle vi labview 2012 jitter analysis toolkit help.
The dc signal has a voltage that is proportional to the input frequency and can therefore be scaled to that frequency value. At higher frequencies, the timer output frequency and duty cycle depend on the load impedance and the supply. How to measure the duty cycle of pwm wave national instruments. For frequency measurements, the counters support a dynamic averaging mode allowing you to obtain frequency measurements that are optimized for accuracy and latency from 0 hz up to. Keithleys series 2400 source measure unit smu instruments are designed specifically for test applications that demand tightly coupled sourcing and measurement. Third, rightclick the property configuration interface and select the counter in the dedicated digital configuration. Picoscope 5000 oscilloscope software pico technology. In our case its a unity value varying between 0 0% and 1 100%. The media on which you receive national instruments software are warranted not to fail to. The ni 9361 counters provide enhanced frequency and duty cycle pwm measurements. Each timer can generate a programmable width pulse with a softwareselectable frequency in the range of 0.
The digilent waveforms toolkit for labview makes it easy to automate your digilent instruments with labview software. Thorlabs specializes in the building blocks for laser and fiber optic systems. The duty cycle of a bilevel pulse is the ratio of average power to peak power. Study of the algorithm of auto wheel speed sensor testing. Hello, i am using a labjack u6 module with labview 2011. You will learn about programming finite and continuous acquisitions, as well as best practices in hardware software timing, triggering, and logging. If the duty cycle has not been changed, the false case of the case structure executes, and nothing is updated. Duty cycle, sometimes called duty factor, is expressed as a percentage of on time.
Nov 11, 2015 audi p0638, pwm duty cycle explained duration. A 60% duty cycle is a signal that is on 60% of the time and off the other 40%. You will learn about programming finite and continuous acquisitions, as well as best practices in hardwaresoftware timing, triggering, and logging. You dont need the duty cycle measurement part, but the 16bit pwm part is exactly what you want. Data acquisition using labview nxg course overview. The energy in a bilevel, or rectangular, pulse is equal to the product of the peak power, p t, and the pulse width, devices to measure energy in a waveform operate on time scales longer than the duration of a single pulse. Measurement fundamentals badge holders understand the basic concepts of measurement including measurement accuracy, acquisition rates, and signal conditioning.
First, select the scan interface mode in your labview project or ni max. Initially for a set of temperature the duty cycle is generated using pwm by varying the width of the pulse. Duty cycle is the ratio of time a load or circuit is on compared to the time the load or circuit is off. Duty cycle measurement of wireless channels is a spectrum. Iviumsoft provides a range of data analysis options, including. Labview is one of the most popular programming languages used by our customers. The ljm library is the high level code library for tseries devices. At higher frequencies, the timer output frequency and duty cycle depend on. Benchvue makes it simple to connect, control instruments, and automate test sequences. Measuring the frequency and period of high frequency signals. In literature, you will often see duty cycle represented as a percentage. The software provides an user interface to set the excitation frequency and its duty cycle. How to use an oscilloscope what is an oscilloscope oscilloscope tutorial. Data acquisition using nidaqmx and labview yotta volt.
Pwm channels specifies the pwm channels to write to. Internal zeroing and calibration while connecting to the dut. The media on which you receive national instruments software are warranted not to fail to execute programming instructions, dueto defects. For example, if a pwm signal has a 10 ms period and its pulses are 2 ms long, that signal is said to have a 20 percent duty cycle. Pdf implementation of a programmable electromechanical. Usb data acquisition modules measurement computing.
851 86 974 469 1154 190 345 3 900 341 1251 1236 1196 540 711 651 150 1417 237 536 339 696 322 1153 1618 303 1555 700 1132 3 140 1436 878 901 804 940 1246 722